Follow these steps to calibrate your 994 Laser machine, including cutter setup and jaw calibration, to ensure accurate key duplication.
Accessing the Calibration Menu
Calibration ensures precise alignment of the cutter, jaws, and tracer point for accurate key duplication.
How to Access the Calibration Menu:
- Go to the SETUP MENU from the Main Menu.
- Select the CALIBRATIONS MENU.
- Choose the appropriate calibration function:
- Cutter Setup – Adjusts the cutter position along the X and Y axes.
- Jaw Setup – Installs and calibrates the jaw for different key types.
- Touch Screen Setup – Adjusts touchscreen settings.
- Tracer Point Reset – Resets tracer point and jaws for accuracy.
Cutter Setup Calibration
Important: Changes must be saved before exiting, or they will be lost.
Steps to Calibrate the Cutter Position:
- Go to the CALIBRATIONS MENU and select Cutter Setup.
- Adjust the X-Y axis position using the on-screen buttons.
- The display shows the modifications in real time.
- Press "1" to save changes once the cutter is correctly aligned.
- If needed, reset to the previous setting by pressing "2".
Jaw Setup Calibration
Important: The correct jaw must be selected and calibrated for precise key cutting.
Steps to Calibrate the Jaw Setup:
- Go to the CALIBRATIONS MENU and select Jaw Setup.
- Install the required jaw and select the corresponding jaw code from the JAW SETUP MENU.
- Insert the calibration template when prompted.
- Press "3" to start the self-calibration process.
- Adjust the X-Y axis position using the on-screen buttons if necessary.
- Press "1" to save changes, or "2" to reset to previous settings.
- Follow the on-screen instructions to complete jaw calibration.
By completing these calibration steps, your key cutting machine will operate with maximum precision, ensuring clean and accurate key duplications.