How to Calibrate the Gymkana Key Cutting Machine

Follow these steps to calibrate the Gymkana Key Cutting Machine, including jaw setup, tracer calibration, and tool replacement to ensure accurate key duplication.

Gymkana Key Cutting Machine Manual​

Jaw Setup Calibration

How to Access the Jaw Setup Screen:

  1. From the SETUP menu, select the JAW key.

Jaw Replacement Steps:

  1. Loosen the fixing nut and remove the jaw.
  2. Insert the new jaw and secure it with the fixing nut.
  3. Select the installed jaw (e.g., "C01") on the display.
  4. Modify the X, Y, Z axes if needed.
  5. Press AUTOADJUST to start automatic jaw calibration.
  6. Follow the on-screen instructions for pin removal, tracer insertion, and tip stop.
  7. Press OK to complete the adjustment.

Tracer Calibration

How to Access the Tracer Setup Screen:

  1. From the SETUP menu, select the TRACERS key.

Adjustment Procedure:

  1. Rotate the tracer tower toward the operator.
  2. Select the tracer to be calibrated from the display.
  3. Adjust X, Y, Z axes if necessary.
  4. Press AUTOADJUST to start automatic tracer calibration.
  5. Ensure jaw "C01" is installed.
  6. Press OK to finalize the calibration.

Tool Replacement in the Spindle

Steps to Replace the Cutter or Tracer:

  1. Open the left-side panel of the machine.
  2. Press and turn counterclockwise the handle to loosen the chuck spindle.
  3. Remove the tool from its seat.
  4. Insert the new tool or tracer fully into place.
  5. Secure it by turning the handle clockwise.

For further assistance, refer to the Gymkana manual or contact Keyline Technical Support at techsupport@keyline-usa.com. 🚀