If you're encountering the "Electric Tracer in an Unsafe Status" error on your Keyline machine, follow these specific troubleshooting steps based on your machine model:
Gymkana
-
Check Tracer Type: Ensure the T08 tracer is properly installed in the tracer shaft.
-
Tracer Setup Check: If performing a tracer setup, confirm the T00 tracer is installed in the cutting shaft.
Ninja Total
Cause: This error is often caused by metal chips from cutting keys accumulating in the carriage and causing a short.
Solution:
-
Remove Carriage Cover: Take off the front black carriage cover.
-
Clean the Carriage: Use a vacuum to remove any metal chips or debris.
-
Persistent Issue: If the error remains, contact Keyline Tech Support for repair: techsupport@keyline-usa.com.
Pro Source
-
Check Tracer Type: Ensure the T08 tracer is correctly installed in the tracer shaft.
-
Tracer Setup Check: If performing a tracer setup, confirm the T00 tracer is in the cutting shaft.
Ninja Laser
Cause: This error usually happens when metal chips from key cutting collect inside the carriage, leading to an electrical short.
Solution:
-
Remove Carriage Cover: Take off the front black carriage cover.
-
Clean the Carriage: Use a vacuum to clear away any metal chips or particles.
-
Persistent Issue: If the problem continues, contact Keyline Tech Support for repair: techsupport@keyline-usa.com.
Messenger
For the Messenger machine, contact Keyline Tech Support for assistance: techsupport@keyline-usa.com.
Still Need Help? Reach out to techsupport@keyline-usa.com for additional support.