If you're encountering the "Calibration Tool Not Found" error on your Keyline machine, follow these machine-specific troubleshooting steps:
Ninja Laser
-
Check Tracer Alignment: Ensure TL003 is in the tracer shaft and TL000 is on the jaw.
-
Insert the Calibration Template: Place the silver rectangle with a key ring into the jaw.
-
Confirm Jaw Placement: Ensure the jaw is properly aligned and fully secured.
-
Remove the Tip Stop: This allows the tracer to move freely.
-
Check Tracer Contact: Verify the tracer is aligned with the template—adjust if needed.
Gymkana
-
Tracer Positioning: Ensure T08 is on the right and T00 is on the left.
-
Check Tracer for Straightness: Ensure both tracers are perfectly aligned.
-
Lower and Lock the Tracer Knob: Ensure the knob is securely in the down position.
-
Insert the Calibration Template: Use the silver metal rectangle with a key ring and install it with the rear stoppers.
-
Secure in U Jaw: Push the template firmly into the U Jaw and lock it in place.
Download Gymkana Calibration Guide (PDF)
Pro Source
-
Tracer Positioning: Confirm T08 is on the right and T00 is on the left.
-
Check Tracer for Straightness: Ensure both tracers are perfectly aligned.
-
Lower and Lock the Tracer Knob: Ensure the knob is securely in the down position.
-
Insert the Calibration Template: Use the silver metal rectangle with a key ring and install it with the rear stoppers.
-
Secure in U Jaw: Push the template firmly into the U Jaw and lock it in place.
BD Laser
-
Tracer Check: Ensure the tracer is straight and labeled TL003.
-
Jaw Placement: Verify the correct jaw is fully left in the carriage and secured.
-
Calibration Template: Confirm the silver rectangle with a key ring is properly placed on the jaw.
-
Tracer Contact: Ensure the tracer touches the calibration template—adjust if necessary.
994 Laser
-
Tracer Check: Ensure the tracer is straight and labeled TL003.
-
Jaw Placement: Verify the correct jaw is fully left in the carriage and secured.
-
Calibration Template: Confirm the silver rectangle with a key ring is properly placed on the jaw.
-
Tracer Contact: Ensure the tracer touches the calibration template—adjust if necessary.
Still Need Help? Contact techsupport@keyline-usa.com for assistance.