Fix "Calibration Tool Not Found" Error

If you're encountering the "Calibration Tool Not Found" error on your Keyline machine, follow these machine-specific troubleshooting steps:

Ninja Laser

  1. Check Tracer Alignment: Ensure TL003 is in the tracer shaft and TL000 is on the jaw.

  2. Insert the Calibration Template: Place the silver rectangle with a key ring into the jaw.

  3. Confirm Jaw Placement: Ensure the jaw is properly aligned and fully secured.

  4. Remove the Tip Stop: This allows the tracer to move freely.

  5. Check Tracer Contact: Verify the tracer is aligned with the template—adjust if needed.

Gymkana

  1. Tracer Positioning: Ensure T08 is on the right and T00 is on the left.

  2. Check Tracer for Straightness: Ensure both tracers are perfectly aligned.

  3. Lower and Lock the Tracer Knob: Ensure the knob is securely in the down position.

  4. Insert the Calibration Template: Use the silver metal rectangle with a key ring and install it with the rear stoppers.

  5. Secure in U Jaw: Push the template firmly into the U Jaw and lock it in place.

Download Gymkana Calibration Guide (PDF)

Pro Source

  1. Tracer Positioning: Confirm T08 is on the right and T00 is on the left.

  2. Check Tracer for Straightness: Ensure both tracers are perfectly aligned.

  3. Lower and Lock the Tracer Knob: Ensure the knob is securely in the down position.

  4. Insert the Calibration Template: Use the silver metal rectangle with a key ring and install it with the rear stoppers.

  5. Secure in U Jaw: Push the template firmly into the U Jaw and lock it in place.

BD Laser

  1. Tracer Check: Ensure the tracer is straight and labeled TL003.

  2. Jaw Placement: Verify the correct jaw is fully left in the carriage and secured.

  3. Calibration Template: Confirm the silver rectangle with a key ring is properly placed on the jaw.

  4. Tracer Contact: Ensure the tracer touches the calibration template—adjust if necessary.

994 Laser

  1. Tracer Check: Ensure the tracer is straight and labeled TL003.

  2. Jaw Placement: Verify the correct jaw is fully left in the carriage and secured.

  3. Calibration Template: Confirm the silver rectangle with a key ring is properly placed on the jaw.

  4. Tracer Contact: Ensure the tracer touches the calibration template—adjust if necessary.